Product name : YIDAY Timer Electric Ball Valve
Product No. : 2011527114610
valve size :
|
Details: |
YIDAY Timer Electric Ball Valve
YIDAY Timer Instruction 1 Parameter specifies Working voltage :110~250VDC(110~230VAC) The time for keeping valve open :0 H : 0M :0S --99 H 59 M 59 S The time for keeping valve closed : 0 H : 0M :0S --99 H 59 M 59 S 2 Timer specification 3 Operation instruction Actuator parameter setting have two menu structures on below YIDAY Timer Instruction 1 Parameter specifies Working voltage :110~250VDC(110~230VAC) The time for keeping valve open :0 H : 0M :0S --99 H 59 M 59 S The time for keeping valve closed : 0 H : 0M :0S --99 H 59 M 59 S 2 Timer specification 3 Operation instruction Actuator parameter setting have two menu structures on below: Function code ( fist menu), The setting parameters of function code ( secondary menu)
1: Press 2 seconds and enter to fist menu, the screen display picture 1 text(t on) , indicating enter to set the valve keeping open state . Press again, the screen display picture 2 text (t o FF),indicating enter to set the valve keeping closed state 2: Press then the after entering the stetting state , showing the valve keeping time for setting ( Set the valve keeping open time on the valve keeping open state . Set the valve keeping closed time on the valve keeping closed state.) . Select flashing bit by pressing, and change the numerical by pressing. When " : " is flashing , indicate setting "HS ( hours) :MS(minutes)", and change the flashing fit by pressing. When the " : " is bright , indicate setting " MS(minutes) :SS(seconds) " . The data will be deposited in the valve controller after completing the setting . Press when finish setting , will return fist menu , press again , enter to next fist menu to set parameters 3: Press the&, the screen display picture 5 , indicating open the valve manually. Press the&, the screen display picture 6, indicating closed the valve manually . Exit manual mode to press the& or &. And go the power -on action. 4: On the normal working state, the displayed time is valve keeping time.(e.g. Valve keeping open time is 10 S, will count down 10S) The " : " is flashing , indicating the "HS ( hours) : MS(minutes)"' . The " : " is bright, indicating the " MS(minutes) : SS(seconds) " .
4 Stalling protection function When the actuator is detected stalling, it will run in reverse direction .when reach to the open or closed position , and do the close or open action again , meanwhile displaying flashed 0000-0001 on screen ( indicating the current retrying times ) . If it fail at third retrying , the valve will stop running and display ERRL on the screen . |
Related Products : |